Datacore with Samsung NVme disk, that are seen with the same ID. This must be a bug from Samsung. If you have two NVme disks with the same ID
You only se one disk at the time.
For Datacore this is not good. You want to mirror thoose NVme disk in Datacore.
Workaround, if you dont get the hardware vendor to send new disc.
Edit C:\Program Files\DataCore\SANsymphony\DataCore.Executive.CorePmf.dll.config
____________________________________________________________________________________________
<?xml version=”1.0″?>
<configuration>
<appSettings>
<add key=”Products” value=”PERC,Msft Virtual Disk 1.0,NVMe”/>
</appSettings>
<startup><supportedRuntime version=”v4.0″ sku=”.NETFramework,Version=v4.5″/></startup></configuration>
____________________________________________________________________________________________
REMEMBER to backup this file before upgrade DataCore and restore this before reboot!
Leave a Reply